Available

Breville Dual Boiler

M-054 · BES920XL

$650

  • Breville Dual Boiler BES920XL espresso machine with its portafilter and filter baskets
  • Breville Dual Boiler BES920XL from the front right, filter baskets on the drip tray
  • Close view of the Breville Dual Boiler’s group head, steam wand, portafilter and filter baskets
  • Back panel of the Breville Dual Boiler BES920XL
  • Rating plate on the base of the Breville Dual Boiler BES920XL: model, 120 V, 1700 W
  • Show photo 1 of 5: Breville Dual Boiler BES920XL espresso machine with its portafilter and filter baskets
  • Show photo 2 of 5: Breville Dual Boiler BES920XL from the front right, filter baskets on the drip tray
  • Show photo 3 of 5: Close view of the Breville Dual Boiler’s group head, steam wand, portafilter and filter baskets
  • Show photo 4 of 5: Back panel of the Breville Dual Boiler BES920XL
  • Show photo 5 of 5: Rating plate on the base of the Breville Dual Boiler BES920XL: model, 120 V, 1700 W

Condition

Used; extensively serviced; normal cosmetic scratches and wear

Included

  • 58 mm portafilter
  • Four filter baskets
  • Water-filter holder

Features

  • Separate brew and steam boilers
  • PID temperature control
  • 58 mm heated group
  • Programmable controls
  • Pressure gauge
  • LCD / shot timer
  • Hot-water outlet
  • Steam wand
  • 84 oz reservoir

Specifications

Exterior
Brushed stainless steel / silver
Voltage
120 V
Power
1700 W
Country of origin
China

Service record SR-9 · Recommissioned

M-054 · BES920XL · Completed Oct 2026

Presented

Machine arrived functional but exhibited extensive scale around upper steam-boiler fittings and leakage after affected hoses/seals were disturbed. Cracking was visible along the bottom of the reservoir.

Findings
  • Scale deposits were concentrated on the top of the steam boiler near upper fittings and probes.
Work
  • Completed deep manual descaling and repeated flushing until visible scale debris cleared.
  • Cleaned boiler level probes and serviced the steam-boiler vacuum breaker.
  • Replaced boiler seals/O-rings, grouphead gasket and one PTFE pump-to-boiler pressure hose.
  • Cleared a scale-obstructed steam-boiler outlet/drain and freed a bound one-way fill valve; backflushed and detailed the machine.
Tested
  • Brew, hot-water and steam functions verified after service.
  • Reservoir held full without observed leakage during testing.
  • Completed eight days of functional test use without recurrence of service-cycle fault codes.
  • Pump and solenoid coil resistances checked against known-good comparisons.
All available machines